Guide9 min read
Product release after transport: from manual review to release by exception
Before a shipment of medicines goes into stock, its transport record is reviewed and the product released. Key considerations: what the receiving site checks, why manual review is slow, and what has to be in place to release by exception, so that only the shipments that need a person reach one.
On this page
Product release after transport is the quality decision that moves a received shipment of medicines out of quarantine and into saleable or usable stock, once its transport record shows the product stayed within its agreed conditions. Release by exception automates that decision: a validated system checks each shipment's temperature record against criteria the quality team has approved in advance from the product's stability data, releases the product when the record meets them, and sends only the exceptions to a person.
This is the receiving site's release, made by its quality function under the receipt and disposition rules of good distribution practice (GDP). It is not the certification of a batch by a Qualified Person (QP) under Annex 16 of the EU guide to good manufacturing practice (GMP), and it is not the approval of a drug product by the quality control unit under 21 CFR 211.22 in the US. Those happen once per batch, at the manufacturer or importer, and certification stays with a person: where a computerized system is used to record certification and batch release, Annex 11 asks that only a Qualified Person be able to certify, using an electronic signature. This one happens where the shipment lands.
Three releases that are easy to confuse
| Release | What is decided | Who decides | Where the rule is |
|---|---|---|---|
| QP certification (EU) | Whether the batch was made and checked in line with GMP and its marketing authorization | A Qualified Person of the manufacturer or importer | EU GMP Annex 16 |
| Quality unit approval (US) | Whether the drug product is approved or rejected | The manufacturer's quality control unit | 21 CFR 211.22 and 211.142 |
| Release after transport | Whether this shipment arrived within its conditions, so the product can go into stock | The receiving site's quality function, under its written procedures; at an EU wholesaler, within the quality system the Responsible Person answers for | EU GDP sections 3.2, 5.4, and 9.2; World Health Organization (WHO) TRS 1025, Annex 7, 12.16 and 12.17. In the US, 21 CFR 205.50, the minimum for state licensing of wholesale distributors, asks only that incoming shipping containers be examined and that receipt follows written procedures; it does not mention the transport temperature record |
Annex 16 names the link between them. Batch release, it says, ends with the transfer to saleable stock, which has to take the QP's certification into account, and where that transfer happens at another site, the arrangement is set down in a written agreement between the sites. The EU GDP guidelines say the same from the receiving end: batches go into saleable stock only once the site has assurance, under written procedures, that they are authorized for sale.
The two can overlap: where a batch travels before it is certified, as when finished product made outside the EU is shipped to the importing site, Annex 16 asks the QP to take the conditions of storage and transport into account before certifying it, so the transport record becomes part of the certification.
The rest of the EU guidelines are covered in our guide to good distribution practice.
What the quality team checks on receipt
The guidance sets the checks in general terms. EU GDP asks the receiving function to confirm that the consignment is correct, comes from an approved supplier, and has not been visibly damaged, and to move products that need special storage into it first. WHO adds that the transport temperature data, where appropriate, is reviewed on receipt, to make sure the required conditions were maintained, and that nothing goes into saleable stock until an authorized release is obtained. In practice, the review covers five things:
- The record against the range
- Every reading compared with the range on the label or agreed with the manufacturer. EU GDP asks that storage conditions be kept, in transit, within the limits the manufacturer describes or the outer packaging states.
- The excursions
- each period outside the range, with how long it lasted and how far it went. Under EU GDP, an excursion in transit is reported to the distributor and the recipient and investigated under a written procedure, whatever the release decision.
- The stability budget
- for a product that has one, how much of its allowed time outside the storage condition this shipment used, and how much is left for the rest of the chain.
- Completeness
- whether the record covers the whole journey without gaps and belongs to this shipment. A gap in the record is a period nobody can account for.
- The chain of custody
- whether the shipment came from the expected sender and arrived where it was meant to, with seals intact and no signs of tampering. WHO lists seal intactness and signs of tampering among the checks at receipt, and EU GDP requires delivery to the address on the delivery note.
Why manual review is slow
When the record comes from a device read on arrival, the review cannot start until someone has found the device in the shipment, stopped it, read it out, and filed the result, often as a PDF report. A reviewer then opens the file, checks the readings against the product's limits, and signs the release or raises a deviation.
The product waits in quarantine the whole time, held apart from saleable stock until someone decides.
The cost sits in the clean records. Where most shipments arrive within their range, a manual process still reviews every one with the same care, so the queue is set by volume rather than by risk.
Defining release by exception
Release by exception turns that around. The quality team agrees in advance, in writing, what a releasable record looks like for each product. A validated system checks each arriving record against those criteria. Records that meet them are released without a person reviewing them; records that do not, or that cannot be evaluated, go to a person, who decides as before.
None of the GDP or GMP texts cited here uses the phrase, and none of them requires automated release. What they do set are the conditions a system that makes routine quality decisions has to meet.
Automating release from the temperature record, step by step
Set the criteria
For each product: its temperature range, its stability budget and how much of it a shipment may use, any limit on freeze and thaw cycles, and what counts as a complete record. The criteria come from the manufacturer's stability data and are approved in the quality system like any other procedure.
Capture the record
Each shipment carries a device whose readings are tied to that shipment and kept in a validated system with an audit trail.
Evaluate on arrival
When the shipment is received, the system checks each product's record against that product's criteria: range, excursions, budget, and completeness.
Release or route
A record that meets every criterion is released, and the release is recorded with the criteria it was judged against. A record that fails any of them, or is incomplete, stays in quarantine and goes to a person.
Review the exceptions and the system
A person decides the exceptions as before. The system itself is evaluated periodically, as EU GMP Annex 11 asks of computerized systems, to confirm it remains in a valid state.
What has to be in place
Automating the decision does not lower the bar it has to meet. Annex 11, the EU GMP guidance on computerized systems, puts it in one sentence: where a computerized system replaces a manual operation, there should be no resultant decrease in product quality, process control, or quality assurance.
- A validated system
- EU GDP: before a computerized system is brought into use, it is shown through validation or verification that it achieves the desired results accurately, consistently, and reproducibly. In the US, 21 CFR Part 11 asks for systems holding electronic records to be validated for accuracy, reliability, consistent intended performance, and the ability to discern invalid or altered records.
- Electronic quarantine that holds
- EU GDP and WHO both allow product awaiting a decision to be held apart electronically rather than physically, provided the system gives equivalent security and is validated.
- A record whose integrity holds
- The US Food and Drug Administration (FDA) defines data integrity as the completeness, consistency, and accuracy of data, and expects such data to be attributable, legible, contemporaneously recorded, original or a true copy, and accurate, known as ALCOA. Annex 11 asks systems that exchange data electronically to have built-in checks for its correct and secure entry and processing. Automatic criteria are only as good as the record they read.
- Approved criteria and stability data
- the criteria rest on the product's stability data, which comes from the manufacturer or marketing authorization holder, and they are approved before use. A product without stability data covering the conditions in question has nothing to automate, and stays with a person.
- An audit trail
- 21 CFR 11.10(e) asks for secure, computer-generated, time-stamped audit trails of the actions that create, modify, or delete electronic records. Annex 11 asks for such an audit trail to be considered on the basis of risk, for the reason behind any change or deletion of GMP-relevant data to be documented, and for audit trails to be regularly reviewed. With one in place, every automatic release, and every change to a criterion, can be traced.
- Written agreements
- EU GDP requires a written contract that clearly sets out each party's duties for any outsourced activity, and Annex 11 requires formal agreements with third parties that provide or support a computerized system. Where the record comes from a monitoring provider, the quality agreement says who supplies the data, who sets the criteria, and who decides the exceptions.
- Named accountability
- the decision stays with the people the rules name. Under EU GDP the Responsible Person may delegate duties but not responsibilities, and under 21 CFR 211.22 the quality control unit has the responsibility and authority to approve or reject drug products. Release by exception hands over the routine work, not the responsibility for it.
What 21 CFR Part 11, Annex 11, and ALCOA+ ask of the record and of the system that holds it is set out in our guide to data integrity for temperature records.
Excursions within a stability budget
An excursion is not the same as damage. Whether the product can still be used is judged against its stability data, and many products have data that allows some time outside the storage condition without significant risk to quality. That allowance, the stability budget, is cumulative: every excursion in the product's life spends part of it.
This is what makes release by exception more than a check that the record stayed in range. If the criteria include the budget, a shipment with an excursion the budget absorbs can be released automatically, because the decision a person would have made from the same stability data is already written into the criteria. A shipment that goes beyond the budget, or a product with no agreed budget, goes to a person.
Two things do not change. Under EU GDP, the excursion is still reported to the distributor and the recipient, and handled under the procedure for investigating excursions, even when the product is released. And the part of the budget the shipment used is spent: the next site can judge only against what is left, which is why a product with a small budget needs its exposure tracked at each step of the chain.
How excursions are defined, reported, and assessed is in our guide to temperature excursions, and where a single summary figure can and cannot be used in that assessment is in our guide to mean kinetic temperature.
Where the record comes from
Release by exception needs the record in the system when the shipment arrives. A device read on arrival can feed it once someone has read it out. A device that reports during the trip has the record complete as the shipment lands, so the evaluation can run at receipt. How the device types differ is in our guide to cold chain monitoring devices, and the case for reporting in transit, with the cases where it does not pay, in Why real-time temperature monitoring, and when it isn't worth it.
Where Controlant fits
Controlant's Zero-Touch Release releases pharmaceutical products for further processing or distribution when every product in the shipment stayed within its stability budget, including a product that had an excursion the budget absorbed. Each product is checked on arrival against its own digitized stability profile, and only a product beyond its budget goes to the customer's quality team. The Controlant Platform is validated to comply with FDA 21 CFR Part 11 and EU GMP Annex 11. At Roche, the approach has automated up to 99.5% of product releases with no human intervention, according to a joint Roche and Controlant presentation at LogiPharma EU 2023.
Sources
- 1Guidelines on Good Distribution Practice of medicinal products for human use (2013/C 343/01), sections 2.2, 3.2, 3.3.1, 5.4, 7.1, 7.2, and 9.2European Commission, Official Journal of the European Union C 343, 23 November 2013
- 2EudraLex Volume 4, Annex 16: Certification by a Qualified Person and Batch Release (2015), scope, general principles, 1.1, 1.5.3, and glossaryEuropean Commission
- 3EudraLex Volume 4, Annex 11: Computerised Systems (2011), principle and sections 3.1, 5, 9, 11, and 15European Commission
- 4Good storage and distribution practices for medical products, TRS 1025, Annex 7 (2020), glossary and sections 12.16, 12.17, 12.26, 18.6, and 18.40World Health Organization
- 521 CFR 211.22, Responsibilities of quality control unit; 211.142, Warehousing proceduresUS Code of Federal Regulations (eCFR)
- 621 CFR 205.50, Minimum requirements for the storage and handling of prescription drugsUS Code of Federal Regulations (eCFR)
- 721 CFR 11.10, Controls for closed systems, paragraphs (a) and (e)US Code of Federal Regulations (eCFR)
- 8Data Integrity and Compliance With Drug CGMP: Questions and Answers, Guidance for Industry (December 2018)US Food and Drug Administration
- 9Product Stability Automation, Roche with Controlant, LogiPharma Europe 2023Controlant
Questions people ask
How do you automate product release from shipment temperature data?
Agree in writing, for each product, what a releasable record looks like: its temperature range, its stability budget and how much a shipment may use, and what counts as a complete record, all based on the manufacturer's stability data. A validated system checks each arriving shipment's record against those criteria, releases the product when every criterion is met, records the release with the criteria it was judged against, and sends any record that fails or cannot be evaluated to a person.
What is release by exception?
A way of releasing received product in which records that meet pre-approved, documented criteria are released automatically by a validated system, and only the records that do not, or cannot be evaluated, go to a person for review.
Is product release after transport the same as QP release?
No. QP certification under EU GMP Annex 16 confirms once per batch that it was made and checked in line with GMP and its marketing authorization. Release after transport is the receiving site's decision that a particular shipment arrived within its conditions and can go into stock.
Can a product be released after a temperature excursion?
Yes, if the product's stability data shows the exposure has no significant effect on its quality, for example because the excursion stayed within its stability budget. Under EU GDP the excursion is still reported to the distributor and the recipient, and handled under the procedure for investigating excursions.
Does GDP allow automated release of shipments?
EU GDP neither requires automated release nor mentions it. It requires computerized systems to be validated before use, and allows product awaiting a decision to be segregated electronically if the system gives equivalent security and is validated.
Who is responsible when release is automated?
The same people as before. Under EU GDP the Responsible Person may delegate duties but not responsibilities, and under 21 CFR 211.22 the quality control unit keeps the authority to approve or reject drug products.
More guides
All insightsGuide9 min read
Data integrity
What 21 CFR Part 11, Annex 11, and ALCOA+ ask of a shipment's temperature record.
Read the guideGuide9 min read
Shipping with dry ice
UN 1845 by air and road, how long a packout lasts, and colder still in dry shippers.
Read the guideGuide6 min read
Temperature excursions
Defining, measuring, and dealing with them.
Read the guideSee what this looks like in the platform
Tell us what you ship and where, and we'll show you the platform on routes and products like yours.