Saga Dry Ice: Dry-ice shipments, measured in the payload
The PR-T80 probe reads to −95 °C from inside the dry ice while the device itself rides outside it, reporting temperature, location, and light in real time. Calibrated at −80, −40, and 0 °C, accurate to ±1.0 °C.

- Operating range
- −95 to +50 °C
- Through the PR-T80 probe
- Accuracy
- ±1.0 °C
- Housing
- 61 × 98 mm
- 25 mm deep, 194 g
- IP rating
- IP54
Key capabilities
The probe goes where the product is
The probe, 1370.8 mm overall, reaches into the shipper; the device stays at −20 to +50 °C, where it reports in real time.
Calibrated for dry ice
−80, −40, and 0 °C against a NIST-traceable standard, ±1.0 °C, 0.1 °C resolution.
Same fleet, same platform
The same Saga-P housing as the rest of the fleet, and every reading lands in the Controlant Platform beside the rest of the lane.
Specifications
Built for dry ice down to −95 °C
Full specifications from the Saga Dry Ice datasheet, version 2, 7 April 2026.
Limited range
The probe reads to −95 °C. The device itself rides outside the dry ice at −20 to +50 °C; between −30 and −20 °C it still logs, with reduced battery life, but stops reporting in real time.
| Model | Saga Dry Ice |
|---|---|
| Standard operating range | −95 to +50 °C |
| Probe | PR-T80 digital temperature probe |
| Calibration points | −80, −40, 0 °C on the probe, NIST traceable |
| Accuracy | ±1.0 °C |
| Resolution · long-term drift | 0.1 °C · under 0.1 °C per year |
| Logging · reporting | Logs every 10 minutes · reports in real time every 1 to 24 hours, and on any excursion |
| Battery | 2500 mAh rechargeable NiMH, not dangerous goods, at least 70 charge cycles |
| Memory | 150 days of readings at 10-minute intervals |
| Connectivity · location | 4G, 3G, and 2G, global · cellular triangulation and 2.4 GHz Wi-Fi detection |
| Dimensions · weight | 25 × 61 × 98 mm · 194 g |
| Housing · ingress protection | ABS · IP54 |
| Approvals | CE, FCC, IC, NOM, KC · IATA, FAA, and EASA flight compliance |
Battery life
Set the wake-up interval, read the days
A fully charged device on the interval shown reports in real time and raises alarms for at least this long while monitoring a shipment inside its operating range. Below 5% charge it hibernates: it keeps logging to memory and stops reporting until recharged.
| Wake-up interval | 2500 mAh |
|---|---|
| 1 hour | 20 days |
| 2 hours | 35 days |
| 3 hours | 45 days |
| 6 hours | 75 days |
| 12 hours | 110 days |
| 24 hours | over 110 days |
Dry ice, in real time
Dry-ice shipments sublimate on a schedule nobody controls, and a passive logger read on arrival tells you afterwards. Saga Dry Ice reports in real time on its wake-up interval and the moment the temperature leaves its limits, so a re-icing can be arranged while the shipment is still in transit.
Device management is handled
Return logistics, calibration, and servicing are ours to run, which keeps a device and its probe in circulation rather than in a drawer.
Questions about Saga Dry Ice
How cold can Saga Dry Ice measure?
The PR-T80 probe reads to −95 °C. It is calibrated at −80, −40, and 0 °C on the probe, and accurate to ±1.0 °C.
Where does the device sit in a dry ice shipment?
Outside the dry ice, in its own −20 to +50 °C band, with only the probe in the cold. Between −30 and −20 °C the device still logs, with reduced battery life, but stops reporting in real time.
Is it the same device as Saga Cryogenic?
Same Saga-P housing and the same PR-T80 probe. What differs is the calibration and the accuracy bands: Dry Ice is calibrated at −80, −40, and 0 °C on the probe and reads to −95 °C; Cryogenic adds a −196 °C point and reads to −200 °C.
Questions about Saga devices?
Tell us what you ship and where, and someone from our team will get back to you.