Skip to content

Saga Dry Ice

Saga Dry Ice: Dry-ice shipments, measured in the payload

The PR-T80 probe reads to −95 °C from inside the dry ice while the device itself rides outside it, reporting temperature, location and light in real time. Calibrated at −80, −40 and 0 °C, accurate to ±1.0 °C.

Saga Dry Ice device, white at the top and navy from the screen down, PR-T80 probe attached and coiled below it, screen reading −94.7 °C
Saga Dry Ice, 25 × 61 × 98 mm, 194 g. Drawn to scale on the housing's 61 mm width beside a credit card (ISO/IEC 7810 ID-1).Source: Saga Dry Ice datasheet, with the PR-T80 probe
Operating range
−95 to +50 °C
Through the PR-T80 probe
Accuracy
±1.0 °C
Housing
61 × 98 mm
25 mm deep, 194 g
IP rating
IP54

Key capabilities

  1. The probe goes where the product is

    A 1.0 m probe reaches into the shipper; the device stays at −20 to +50 °C, where it reports in real time.

  2. Calibrated for dry ice

    −80, −40 and 0 °C against a NIST-traceable standard, ±1.0 °C, 0.1 °C resolution.

  3. Same fleet, same platform

    The same Saga-P housing as the rest of the fleet, and every reading lands in the Controlant Platform beside the rest of the lane.

Specifications

The same rows as every Saga, read from the datasheet

version 2 · 7 April 2026 · 394 KB. Where a figure is missing from the sheet the row says so rather than borrowing from another model.

Limited range

The probe reads to −95 °C. The device itself rides outside the dry ice at −20 to +50 °C; between −30 and −20 °C it still logs, with reduced battery life, but stops reporting in real time.

Specifications
ModelSaga Dry Ice
Standard operating range−95 to +50 °C
ProbePR-T80 digital temperature probe
Calibration points−80, −40, 0 °C on the probe, NIST traceable
Accuracy±1.0 °C
Resolution · long-term drift0.1 °C · under 0.1 °C per year
Logging · reportingLogs every 10 minutes · reports in real time every 1 to 24 hours, and on any excursion
Battery2500 mAh rechargeable NiMH, not dangerous goods, at least 70 charge cycles
Memory150 days of readings at 10-minute intervals
Connectivity · location4G, 3G and 2G, global · cellular triangulation and 2.4 GHz Wi-Fi detection
Dimensions · weight25 × 61 × 98 mm · 194 g
Housing · ingress protectionABS · IP54
ApprovalsCE, FCC, IC, NOM, KC · IATA, FAA and EASA flight compliance

Battery life

Set the wake-up interval, read the days

A fully charged device on the interval shown reports in real time and raises alarms for at least this long while monitoring a shipment inside its operating range. Below 5% charge it hibernates: it keeps logging to memory and stops reporting until recharged.

Battery life by wake-up interval
Wake-up interval2500 mAh
1 hour20 days
2 hours35 days
3 hours45 days
6 hours75 days
12 hours110 days
24 hoursover 110 days

Dry ice, in real time

Dry-ice shipments sublimate on a schedule nobody controls, and a passive logger read on arrival tells you afterwards. Saga Dry Ice reports in real time on its wake-up interval and the moment the probe leaves its boundaries, so a re-icing can be arranged while the shipment is still in transit.

Device management is handled

Return logistics, calibration and servicing are ours to run, which keeps a device and its probe in circulation rather than in a drawer.

Questions about Saga Dry Ice

How cold can Saga Dry Ice measure?

The PR-T80 probe reads to −95 °C. It is calibrated at −80, −40 and 0 °C on the probe, and accurate to ±1.0 °C.

Where does the device sit in a dry ice shipment?

Outside the dry ice, in its own −20 to +50 °C band, with only the probe in the cold. Between −30 and −20 °C the device still logs, with reduced battery life, but stops reporting in real time.

Is it the same device as Saga Cryogenic?

Same Saga-P housing and the same PR-T80 probe. What differs is the calibration and the accuracy bands: Dry Ice is calibrated at −80, −40 and 0 °C on the probe and reads to −95 °C; Cryogenic adds a −196 °C point and reads to −200 °C.

Questions about Saga devices?

Tell us what you ship and where, and someone from our team will get back to you.